MASSEY-FERGUSON
► PAINT SHOP CONVEYOR CHAIN
► TENSION PRE LOAD WENT FORM 55-60 PSI TO 25 PSI
► LINKS HAD COATING OF OIL, AFTER 2 WEEKS
► THE AMPERAGE DROPED 10 TO 24 PERCENT
CUSTOMER TESTIMONIAL
CUSTOMER & TEST PROFILE
The application:
The paint shop conveyor.
Problem:
Ensuring lubrication of chain whilst operating in a series of hostile environ-
ments, including: water, heat, and paint.
Tension pre load, via pneumatic ram, at 55-60 psi to ensure smooth running.
Details:
The Petron Plus Formula 7 Industrial Super Lube was mixed at 10% of oil
volume, was supplemented to the existing lubricant. This new mixture was Since the introduction of Petron
applied via an automatic applicator system, designed to apply oil where re- Plus Formula 7 Industrial Super
quired and reduce unwanted contamination from excess lubricants. This is Lube on to the conveyor chain, it
normally applied once a week for a complete circuit of the chain. has been necessary to remove
several links from the chain for
maintenance reasons. We were
CUSTOMER TESTS & REPORTS very pleased to see that the links
had a coating of oil on the inside,
Results: even after an extended period of
The chain ran smoother to the extent that pre load via the tension unit was 2 weeks between oiling.
reduced to 25 psi.
Before After
Petron Plus ISL Petron Plus ISL
Sept. 7 Sept. 14 -%
Drive A 5.0 amps 4.0 amps 3.8 amps 24
Drive B 5.0 amps 4.2 amps 4.2 amps 16
Drive C 3.4 amps 3.2 amps 3.0 amps 12
Drive D 3.0 amps 2.8 amps 2.7 amps 10
Conveyor speed
Set at ft/min. 10 11 11
PETRON PLUS GLOBAL, INC.
TM
P.O. BOX 1906 HUTCHINSON, KS 67504 USA, 620/663-1800 Phone, 620/663-8560 Fax,
www.petronplus7.com www.petronplusglobal.com